Skip to content

RemoteControlInterfaceConfiguration

HTTP API schema

Movement bounds the device accepts in move messages, refreshed on every discovery. A move outside these bounds is rejected with a value-out-of-range error before the device is commanded.

RemoteControlInterfaceConfiguration fields

minVelocitynumber

Lowest accepted move velocity in metres per second. Negative values reverse.

maxVelocitynumber

Highest accepted move velocity in metres per second.

minOmeganumber

Lowest accepted move omega in radians per second. Negative values turn right (clockwise seen from above).

maxOmeganumber

Highest accepted move omega in radians per second. Positive values turn left (counter-clockwise seen from above).

minDurationinteger

Shortest accepted move duration in milliseconds.

maxDurationinteger

Longest accepted move duration in milliseconds.

durationIncrementinteger

Granularity of move durations in milliseconds. The device runs moves only in whole multiples of this, so duration must be a multiple of it between minDuration and maxDuration; any other duration is rejected with value-out-of-range.